Technical parameter
Installation dimensions
Model description
Working Principle
Technical parameter
Installation dimensions
Model description
Model | Description | |
TYP802 | ||
Valve type | TYP800 | Split type |
TYP801 | High side angle type | |
TYP802 | High side Z type | |
TYP803 | Integral type | |
Actuator | A | Single spring film type cylinder |
B | Multi spring film type cylinder | |
C | Piston type single acting cylinder | |
C1 | Double acting cylinder | |
D | Electric | |
G | Gas-liquid dynamic | |
H | Electro hydraulic power | |
Steam flow | t/h | Steam circulation tonnage per hour |
First grade steam pressure | P1 | P1<=10Mpa |
Second grade steam pressure | P2 | P2≤0.98MPa时,The change range of P2 is P2±0.4MPa; 0.98<P2≤3.82MPa时,The change range of P2 is P2±0.06MPa; P2>3.82MPa时,The change range of P2 is P2±0.15MPa。 |
First grade steam temperature | t1 | t1<=540℃ |
Second grade steam temperature | t2 | t2±4℃ |
Pressure relief valve diameter | DN15-DN500 | |
Temperature reducing valve diameter | DN15-DN500 | |
Outlet device diameter | DN40-DN1000 | |
remarks | Other description | |
Sample: TYP800-B-40t/h-4Mpa/1Mpa-400℃/190℃-DN25-DN20-DN50-WCB Split, multi spring film, the steam flow 40t/h, the valve before the pressure 4Mpa, the valve after the pressure 1Mpa, the valve temperature of 400, Valve temperature 190 degrees Celsius, the pressure relief valve diameter DN25, the temperature valve diameter DN20, outlet device diameter DN50, cast steel material。 |